Young Researcher Paper Award 2023
🥇Winners

Notice of retraction
Vol. 34, No. 8(3), S&M3042

Notice of retraction
Vol. 32, No. 8(2), S&M2292

Print: ISSN 0914-4935
Online: ISSN 2435-0869
Sensors and Materials
is an international peer-reviewed open access journal to provide a forum for researchers working in multidisciplinary fields of sensing technology.
Sensors and Materials
is covered by Science Citation Index Expanded (Clarivate Analytics), Scopus (Elsevier), and other databases.

Instructions to authors
English    日本語

Instructions for manuscript preparation
English    日本語

Template
English

Publisher
 MYU K.K.
 Sensors and Materials
 1-23-3-303 Sendagi,
 Bunkyo-ku, Tokyo 113-0022, Japan
 Tel: 81-3-3827-8549
 Fax: 81-3-3827-8547

MYU Research, a scientific publisher, seeks a native English-speaking proofreader with a scientific background. B.Sc. or higher degree is desirable. In-office position; work hours negotiable. Call 03-3827-8549 for further information.


MYU Research

(proofreading and recording)


MYU K.K.
(translation service)


The Art of Writing Scientific Papers

(How to write scientific papers)
(Japanese Only)

Sensors and Materials, Volume 20, Number 7 (2009)
Copyright(C) MYU K.K.
pp. 341-349
S&M731 Research Paper of Special Issue
https://doi.org/10.18494/SAM.2009.570
Published: February 2, 2009

Thermal-Type Blood Flow Sensor on Titanium Microneedle [PDF]

Takashi Mineta, Yuki Tanahashi, Eiji Makino, Satoshi Toh, Takahiro Kawashima and Takayuki Shibata

(Received August 15, 2008; Accepted November 18, 2008)

Keywords: thermal flow sensor, Ti needle, blood flow, electrochemical etching

A design of a novel wireless implantable blood pressure sensing microsystem for advanced biological research is presented. The system employs a miniature instrumented elastic cuff, wrapped around a blood vessel, for small laboratory animal real-time blood pressure monitoring. The elastic cuff is made of biocompatible soft silicone material by a molding process and is filled by insulating silicone oil with an immersed MEMS capacitive pressure sensor interfaced with low-power integrated electronic system. This technique avoids vessel penetration and substantially minimizes vessel restriction due to the soft cuff elasticity, and is thus attractive for long-term implant. The MEMS pressure sensor detects the coupled blood pressure waveform caused by the vessel expansion and contraction, followed by amplification, 11-bit digitization, and wireless FSK data transmission to an external receiver. The integrated electronics are designed with capability of receiving RF power from an external power source and converting the RF signal to a stable 2 V DC supply in an adaptive manner to power the overall implant system, thus enabling the realization of stand-alone batteryless implant microsystem. The electronics are fabricated in a 1.5 μm CMOS process and occupy an area of 2 mm × 2 mm. The prototype monitoring cuff is wrapped around the right carotid artery of a laboratory rat to measure real-time blood pressure waveform. The measured in vivo blood waveform is compared with a reference waveform recorded simultaneously using a commercial catheter-tip transducer inserted into the left carotid artery. The two measured waveforms are closely matched with a constant scaling factor. The ASIC is interfaced with a 5-mm-diameter RF powering coil with four miniature surface-mounted components (one inductor and three capacitors) over a thin flexible substrate by bond wires, followed by silicone coating and packaging with the prototype blood pressure monitoring cuff. The overall system achieves a measured average sensitivity of 7 LSB/mmHg, a nonlinearity less than 2.5% of full scale, and a hysteresis less than 1% of full scale. From noise characterization, a blood vessel pressure change sensing resolution of 1 mmHg can be expected. The system weighs 330 mg, representing an order of magnitude mass reduction compared with state-of-the-art commercial technology.

Corresponding author: Peng Cong


Cite this article
Takashi Mineta, Yuki Tanahashi, Eiji Makino, Satoshi Toh, Takahiro Kawashima and Takayuki Shibata, Thermal-Type Blood Flow Sensor on Titanium Microneedle, Sens. Mater., Vol. 20, No. 7, 2009, p. 341-349.



Forthcoming Regular Issues


Forthcoming Special Issues

Applications of Novel Sensors and Related Technologies for Internet of Things
Guest editor, Teen-Hang Meen (National Formosa University), Wenbing Zhao (Cleveland State University), and Cheng-Fu Yang (National University of Kaohsiung)
Call for paper


Special Issue on Advanced Data Sensing and Processing Technologies for Smart Community and Smart Life
Guest editor, Tatsuya Yamazaki (Niigata University)
Call for paper


Special Issue on Advanced Sensing Technologies and Their Applications in Human/Animal Activity Recognition and Behavior Understanding
Guest editor, Kaori Fujinami (Tokyo University of Agriculture and Technology)
Call for paper


Special Issue on International Conference on Biosensors, Bioelectronics, Biomedical Devices, BioMEMS/NEMS and Applications 2023 (Bio4Apps 2023)
Guest editor, Dzung Viet Dao (Griffith University) and Cong Thanh Nguyen (Griffith University)
Conference website
Call for paper


Special Issue on Piezoelectric Thin Films and Piezoelectric MEMS
Guest editor, Isaku Kanno (Kobe University)
Call for paper


Special Issue on Advanced Micro/Nanomaterials for Various Sensor Applications (Selected Papers from ICASI 2023)
Guest editor, Sheng-Joue Young (National United University)
Conference website
Call for paper


Copyright(C) MYU K.K. All Rights Reserved.